sane-coolscan
5
4 July 2000
sane-backends 1.0.19
SANE Scanner Access Now Easy
  • NAME
      sane-coolscan - SANE backend for Nikon film-scanners
  • ABOUT THIS FILE

      This file is a short description of the coolscan-backend for sane!
  • DESCRIPTION

      The sane-coolscan library implements a SANE backend that provides the interface to the following Nikon Coolscan Film scanners: Nikon LS20, LS30, LS1000, LS2000.
      Even though the backend has worked for a number of people, there are still some problems, especially in combination with some SCSI card/drivers (AHA-1505/aha152x.o) and the autofocus command. You should consider this backend 'alpha' and be careful when using it the first time.
  • CONFIGURATION

      The configuration file for this backend resides in /etc/sane.d/coolscan.conf .
      Its contents is a list of device names that correspond to Nikon Coolscan scanners. Empty lines and lines starting with a hash mark (#) are ignored. A sample configuration file is shown below:
      
       #scsi Vendor Model Type 
       scsi Nikon * Scanner 
       /dev/scanner 
      

      The special device name must be a generic SCSI device or a symlink to such a device. To find out to which device your scanner is assigned and how you have to set the permissions of that device, have a look at sane-scsi.
  • SCSI ADAPTER TIPS

      Some SCSI-adapters and low-level SCSI drivers do not work correctly with this backend and the Coolscan scanners. These systems hang when the autofocus command is send to the Scanner. To see a list of which card/driver combinations work or dont work have a look at: http://andreas.rick.free.fr/sane/autofocus.html.


  • FILES

      The backend configuration file:
      /etc/sane.d/coolscan.conf
      The static library implementing this backend:
      /usr/lib/sane/libsane-coolscan.a
      The shared library implementing this backend:
      /usr/lib/sane/libsane-coolscan.so (present on systems that support dynamic loading)
  • ENVIRONMENT

      SANE_DEBUG_COOLSCAN
      If the library was compiled with debug support enabled, this environment variable controls the debug level for this backend. E.g., a value of 128 requests all debug output to be printed. Smaller levels reduce verbosity: SANE_DEBUG_COOLSCAN values
      Examples:
      on bash:
      export SANE_DEBUG_COOLSCAN=8
      on csh:
      setenv SANE_DEBUG_COOLSCAN 8
  • BUGS

      The autofocus command does not work with some SCSI card/driver combinations

      The gamma table is not implemented for the LS1000 yet.

      The dust-removal is not working yet
  • SEE ALSO

      http://andreas.rick.free.fr/sane/
      The homepage of this backend
      http://www.sema.be/coolscan/
      The original version of the coolscan backend by Didier

      sane(7) , sane-scsi(5)
  • THANKS TO



      Didier Carlier - For writing the original Coolscan backend (without it I would not have started this)

      Oliver Rauch - For adapting xsane so quickly to the infrared stuff.

      All the other people working on SANE.
  • AUTHOR
      Andreas Rick
  • EMAIL-CONTACT
      andreas.rick@free.fr